Power Home UPS Inverter 12V

Technical Specifications

Model FR100, FR400, FR500, FR700, FR900, FR1200
Battery Voltage
12V
Technology
DSP Based Full Bridge Topology
Input/Output Phase
Single Phase
Output Voltage on Inverter Mode
220 ± 2%
Output Frequency on Inverter Mode
50Hz ± 0.1Hz
Changeover Time UPS Mode
<10 ms
Changeover Time INV Mode
<30 ms
Changeover Mains to UPS and UPS to Mains
Automatic
Output Waveform on Backup Mode
Pure Sine Wave
THD
<3% (On Resistive/Linear Load)
Efficiency*
>80%
Charger
CCCV Charger
Charging Current
Up to 15Amp*
Surge Load Capacity
300%
Input Voltage (UPS)
170-260+/-10V
Input Voltage (INV.)
100-290+/-10V
Output Voltage on Mains Mode
Same as Input
Output Frequency on Mains Mode
Same as Input
DISPLAY, PROTECTIONS AND INDICATIONS
Display
16x2 Alpha Numeric LCD Display with LED Indications
Display Parameters
Output Power (Watt), Mains AC Voltage, Output AC Voltage, Temperature (Deg. C), Battery Voltage, Charging (Amp.)
Protections with Buzzer Indications
Low Battery, Overload, Short Circuit, Over Temperature
Auto Reset Features
Yes
NB.The technical specifications and perameters are only for quick reference. For installation and product purchase, kindly take technical expert guidance.